Difference between revisions of "LSI: LSI StorCli Cheatsheet"

From Define Wiki
Jump to navigation Jump to search
m (add howto reset status from UBad to UGood)
Line 31: Line 31:
 
Description = Add VD Succeeded
 
Description = Add VD Succeeded
 
</syntaxhighlight>
 
</syntaxhighlight>
 +
 +
== Extend a RAID6 array (TT) ==
 +
<pre>
 +
[root@storage1 ~]# /opt/MegaRAID/storcli/storcli64 /c0/v239 start migrate type=r6 option=add drives=252:0-1
 +
CLI Version = 007.1705.0000.0000 Mar 31, 2021
 +
Operating system = Linux 3.10.0-1127.el7.x86_64
 +
Controller = 0
 +
Status = Success
 +
Description = Start VD Operation Success
 +
</pre>

Revision as of 12:59, 31 October 2023

Install Process

  unzip 1.19.04_StorCLI.zip 
  cd storcli_all_os/
  cd Linux
  rpm -ivh ./storcli-1.19.04-1.noarch.rpm 
  rpm -qpl storcli-1.19.04-1.noarch.rpm 

# Files are in /opt/MegaRAID/storcli/ 
# add this to you $PATH

Query

  • Get everything
storcli64 /c0 show all
# and for a list of options; storcli64 /c0 show help

Reset UBad to UGood

storcli /c0 /e252 /sall set good

Configuring

  • Example for setting up a RAID60 (on 36 Drives, 18 Drives per array)
[root@oswald ~]# storcli64 /c0 add vd type=raid60 drives=85:0-23,88:0-11 pdperarray=18 
Controller = 0
Status = Success
Description = Add VD Succeeded

Extend a RAID6 array (TT)

[root@storage1 ~]# /opt/MegaRAID/storcli/storcli64 /c0/v239 start migrate type=r6 option=add drives=252:0-1
CLI Version = 007.1705.0000.0000 Mar 31, 2021
Operating system = Linux 3.10.0-1127.el7.x86_64
Controller = 0
Status = Success
Description = Start VD Operation Success