Difference between revisions of "StorCli: LSI Drive firmware update"
Jump to navigation
Jump to search
| Line 1: | Line 1: | ||
To flash the drive firmware you require an LSI raid card and StorCli. | To flash the drive firmware you require an LSI raid card and StorCli. | ||
| + | |||
| + | Run storcli on the respective OS (in this example it was done on Centos) | ||
You need to find out the controller id you wish to target, the expander you wish you target and the slot (drive) you wish to flash. | You need to find out the controller id you wish to target, the expander you wish you target and the slot (drive) you wish to flash. | ||
Revision as of 12:23, 17 October 2014
To flash the drive firmware you require an LSI raid card and StorCli.
Run storcli on the respective OS (in this example it was done on Centos)
You need to find out the controller id you wish to target, the expander you wish you target and the slot (drive) you wish to flash.
All this information can be found using (assuming you already know the controller id):
./storcli64 /c0 show |moreOnce you have the information required you can run the flashing command per drive:
./storcli64 /c0 /e8/s0 download src=/mnt/usb/storcli/0101KX1.binThis is of course a example command, the ids used may change and the firmware directory location will be different.